0.1-2000um Dry Method Automatic Laser Particle Size Analyzer
  • Verified manufacturer
  • Pre-shipment inspection
  • DDP door-to-door

Sourced by GoodsFromChina

  • Free quote, compared across factories
  • Samples consolidated & checked
  • AQL inspection before balance payment
  • Sea, air, express & DDP shipping
< 24hAverage response time
How sourcing works
Inquiry basket0

0.1-2000um Dry Method Automatic Laser Particle Size Analyzer

Laser Particle Size Analyzer Model: NKT2020-H Customizable Made in China

Laser Particle Size Analyzer — Type Static Laser, Application Cement/Mineral Powder. MOQ 1 piece, US$7,000.00 – 12,000.00/piece. Factory-direct from China.

US$7,000.00 – 12,000.00/ piece
Min. order: 1 piece
Type
Static Laser
Application
Cement/Mineral Powder
Warranty
2 Years
Meansure Range
0.1-2000um
Optical Path Calibration
Automatic
Flusing Method
Automatic Instrument Flushing
Reference Particle Size:
Power Requirements:
Model:
pieces
Manufacturer or brand owner?List your productRequest removal

At a glance

Product
0.1-2000um Dry Method Automatic Laser Particle Size Analyzer
Price
US$7,000.00 – 12,000.00 / piece
Minimum order
1 piece
Origin
Shandong, Jinan
Customization
Available
Packaging
Standard Export Wooden Case

Last updated

Specifications

Model NO.NKT2020-H
Warranty2 Years
Meansure Range0.1-2000um
Optical Path CalibrationAutomatic
Flusing MethodAutomatic Instrument Flushing
Executive StandardGB/T 19077-2016/ISO 13320:2009
ApplicationCement/Mineral Powder
Reference Particle SizeD10/D50/D90
Measurement Range Option0.01micron - 2000 Microns
Repeatably Error<0.5%(Average Particle Size of National Samples
SoftwareInclude with The Analyzer
Channel Numbers76
Testing ReportAutomatically Generated After Testing
Testing Speed< 10 Seconds
Operation Temperature0-45 Degree
Power Requirements220V (± 20V), 50Hz - 60Hz
Weight58kgs
Transport PackageStandard Export Wooden Case
Specification98X51X53cm / 58kgs
OriginShandong, Jinan
Production Capacity25/PCS/Month
Package Size105.00cm * 47.00cm * 54.00cm
Package Gross Weight78.000kg
CustomizationAvailable
TypeStatic Laser
Sample FeedingDry Dispersion
Shipping CostContact the supplier about freight and estimated delivery time.
gnNKT2020-L adopts focused Fourier transform test technology to ensure the maximum range in the shortest focal length and effectively improve the resolution of the instrument; the unique arrangement of small probes enables 2020 to have super small particle test ability. The superior automatic alignment system and computer operating system show NKT2020-L humanized design.
High stability optical path optimizationthe unique design makes NKT2020-L have the most advanced high stability optical path, it uses high stability and high power fiber output laser, and the excellent configuration makes NKT2020-L have super stability; the main optical path adopts the full closed design, which ensures the long-term test of the instrument in complex environment.
Special feeding system for pharmaceutical industryNKT2020-L specially developed a special feeding system for pharmaceutical factories. Many medicinal materials with small density, light weight and traditional vibration feeding are difficult to be evenly cut. The newly developed feeding system is changed from passive feeding to active feeding by instruments. Even feeding can ensure the normal test of very light samples.
Unique dry method dispersion systemNKT2020-L dispersion system is optimized based on the French theoretical data, which makes NKT2020-L disperse the dry powder more evenly, super negative pressure ensures the continuity and uniformity of the feed, and effectively avoids the adhesion of the dry powder in the test process.
Dustproof and shockproof designthe whole instrument is sealed, greatly improving the service life of internal components. The unique suspension structure can effectively.
No residual in the pipelineafter the test, there is no residual sample in the pipeline, which will not interfere with the next test.
Computer controlled feedingthe tester can precisely control the feeding amount of the instrument with the help of the computer.
ModelNKT2020-H
ISO 13320-11999
Measurement range0.1
Accuracy error<1%
Model:NKT2020-H
Execution standard:ISO 13320-1:1999;GB/T19077.1-2008
Measurement range:0.1μm -2000μm
Channels number:76
Accuracy error:<1%
Repeatably error:<1%
Automatic testing:It is the first in China to realize one key automatic test, and all operation instruments are automatically completed without the assistance of customers. It is the first real automatic dry test instrument.
Oil free silent air compressorWith dust filtering function to ensure the accuracy of test
Cold dryerFreeze dryer can filter the moisture in the air to ensure the dispersion effect
Misoperation protectionThe instrument has self-protection function for misoperation, and it does not respond to misoperation.
Laser parametersImported fiber output high power laser λ = 650nm, > P > 15MW (constant power, automatic adjustable)
Dispersing methodHigh pressure air dispersion
Operation modeSoftware automatic control operation
Optical alignmentAutomatic proofreading of optical path
96 channel simultaneous acquisition main boardAt present, 96 channels of simultaneous acquisition motherboard are used exclusively in China, which makes the data more accurate and more stable.
Latest active feeding systemThe traditional vibration feeding system is not suitable for the feeding of some new drugs. The newly improved active feeding system can perfectly test all powder samples, and the feeding is even.
Testing speed< 1min / time (excluding sample dispersion time)
volume980mm*410mm*450mm

Product details

0.1-2000um Dry Method Automatic Laser Particle Size Analyzer is a laser particle size analyzer product (static laser) manufactured in China and available to buyers worldwide through the GoodsFromChina sourcing service. Typical uses include Cement/Mineral Powder.

Key features

  • Type: Static Laser
  • Application: Cement/Mineral Powder
  • Warranty: 2 Years
  • Meansure Range: 0.1-2000um
  • Optical Path Calibration: Automatic
  • Flusing Method: Automatic Instrument Flushing
  • Executive Standard: GB/T 19077-2016/ISO 13320:2009
  • Reference Particle Size: D10/D50/D90

gn

NKT2020-L adopts focused Fourier transform test technology to ensure the maximum range in the shortest focal length and effectively improve the resolution of the instrument; the unique arrangement of small probes enables 2020 to have super small particle test ability. The superior automatic alignment system and computer operating system show NKT2020-L humanized design.

High stability optical path optimization

the unique design makes NKT2020-L have the most advanced high stability optical path, it uses high stability and high power fiber output laser, and the excellent configuration makes NKT2020-L have super stability; the main optical path adopts the full closed design, which ensures the long-term test of the instrument in complex environment.

Special feeding system for pharmaceutical industry

NKT2020-L specially developed a special feeding system for pharmaceutical factories. Many medicinal materials with small density, light weight and traditional vibration feeding are difficult to be evenly cut. The newly developed feeding system is changed from passive feeding to active feeding by instruments. Even feeding can ensure the normal test of very light samples.

Unique dry method dispersion system

NKT2020-L dispersion system is optimized based on the French theoretical data, which makes NKT2020-L disperse the dry powder more evenly, super negative pressure ensures the continuity and uniformity of the feed, and effectively avoids the adhesion of the dry powder in the test process.

Ordering & packaging

Minimum order quantity is 1 piece. Standard export packaging: Standard Export Wooden Case. Every order can include a pre-shipment quality inspection and consolidated shipping by sea, air or express, including DDP delivery.

How we source this product for you

  1. 1

    Send your inquiry

    Choose options, quantity and requirements. No payment needed.

  2. 2

    Get a factory quote

    We confirm price, MOQ and lead time — and compare alternatives.

  3. 3

    Production & inspection

    We follow up production and inspect goods before shipment.

  4. 4

    Delivered to your door

    Sea, air or express with customs clearance and DDP options.

Express5–8 days
Air freight8–12 days
Sea freight25–40 days
DDPDuties included

Frequently asked questions

What is the minimum order quantity for 0.1-2000um Dry Method Automatic Laser Particle Size Analyzer?

The MOQ is 1 piece. Smaller trial orders can sometimes be negotiated — tell us your quantity in the inquiry.

How much does 0.1-2000um Dry Method Automatic Laser Particle Size Analyzer cost?

The listed factory price is US$7,000.00 – 12,000.00 per piece, depending on quantity. Your final quote includes our service fee and shipping options.

Can it be customized with my logo or specifications?

Yes. The manufacturer offers customization — logo printing, packaging, colors or modified specifications. Describe your requirements in the inquiry form.

How long does production and shipping take?

Typical production time is 15–45 days depending on quantity. Shipping to the US takes about 5–8 days by express, 8–12 days by air and 25–40 days by sea, with DDP door-to-door delivery available.

How do you check product quality?

We verify the manufacturer before ordering and can perform a pre-shipment inspection (AQL sampling) with a photo report before you pay the balance.

You may also like