Environmental Climatic Constant Rapid Temperature Change Humidity Programmable Climate Test Chamber Equipment /High and Low /Thermal Shock Testing Machine
  • Verified manufacturer
  • Pre-shipment inspection
  • DDP door-to-door

Sourced by GoodsFromChina

  • Free quote, compared across factories
  • Samples consolidated & checked
  • AQL inspection before balance payment
  • Sea, air, express & DDP shipping
< 24hAverage response time
How sourcing works
Inquiry basket0

Environmental Climatic Constant Rapid Temperature Change Humidity Programmable Climate Test Chamber Equipment /High and Low /Thermal Shock Testing Machine

Laboratory Thermostat Model: BS-150AG Customizable Made in China

Laboratory Thermostat made of stainless steel — Type Test Machine, Power 5.5kw. MOQ 1 piece, US$4,750.00 – 6,450.00/piece. QC & shipping by GoodsFromChina.

US$6,450.001 – 4 pieces
US$5,500.005 – 19 pieces
US$4,750.0020+ pieces
Min. order: 1 piece · Lead time: 3-20days
Material
Stainless Steel
Type
Test Machine
Application
Industry, School, Hospital, Lab, Test Equipment
Power
5.5kw
Voltage
380V
Certification
CE, ISO
Customized:
Material:
Voltage:
Power:
Inner Capacity:
pieces
Manufacturer or brand owner?List your productRequest removal

At a glance

Product
Environmental Climatic Constant Rapid Temperature Change Humidity Programmable Climate Test Chamber Equipment /High and…
Price
US$4,750.00 – 6,450.00 / piece
Minimum order
1 piece
Lead time
3-20days
Origin
China
Customization
Available
Certification
CE, ISO
Packaging
Standard Export Strong Plywood Box
HS code
8479899990

Last updated

Specifications

Model NO.BS-150AG
ApplicationIndustry, School, Hospital, Lab, Test Equipment
CustomizedCustomized
CertificationCE, ISO
StructureDevice
MaterialStainless Steel
TypeTest Machine
Voltage380V
Power5.5kw
Gross Weight280kg
Cooling MethodForced Air Cooling
CompressorFrench Taikang
Temperature Range-70℃~150℃
Inner Capacity150L
Lead Time3-20days
PackingWooden Box
ResolutionTemperature: 0.01 °C Deg;
Control StabilityTemperature 0.5°C Deg
Cooling TimeAverage 1 Deg/Min, Non-Linear Cooling
Heating TimeAverage 3 Deg/Min, Non-Linear Heating
Transport PackageStandard Export Strong Plywood Box
Specification500*600*500(W*H*D)
OriginChina
HS Code8479899990
Production Capacity500 Sets Per Month
Package Size150.00cm * 80.00cm * 160.00cm
Package Gross Weight380.000kg
CustomizationAvailable
After-sales Service2 Years
Warranty1 Years
Shipping CostContact the supplier about freight and estimated delivery time.
SummaryTemperature Humidity Climatic Test Chamber
Lateral Structure10
Temperature0.01ºC
Humidity0.1%R.H
Test MethodHigh Temperature
G/BT 2423.4-2008/IEC6008-2-302005
Test DbAlternating Damp Heat Method
Technical StandardsAcceptance shall be conducted in accordance with the signed technical index requirements
The core control logic of the thermal expansion valve isThe opening degree of the expansion valve is controlled by the superheat degree of the gaseous refrigerant at the evaporator outlet, thereby adjusting the flow rate of refrigerant entering the evaporator.
The filter-drier consists of two partsthe filter and the dryer. The filter is used to block solid particles such as iron filings, welding slag, and dirt, preventing them from clogging the passages; the dryer is used to absorb moisture circulating with the refrigerant, avoiding "ice blockage" inside the pipelines.
Compressor Base and Vibration Isolation TreatmentThe base features a water-leakage prevention design. It is a self-evaporating waterproof base that effectively prevents condensed water from leaking out. Vibration isolation treatment is applied to moving components such as the compressor and fan, achieving a low-noise design.
Time0.01
Space RequirementsPositioning & Handling, Installation Footprint Dimensions, and Placement Environment Requirements
Space around the equipment shall comply with the followingA: ≥ 60cm; B≥ 60cm; C≥ 80cm; D≥ 80cm
StandardsThe performance index meets the requirements of GB5170, 2, 3, 5, 6-95 verification methods for basic parameters of environmental test equipment for electrical and electronic products low temperature, high temperature, constant humidity and alternating humidity heat test equipment
ShippingYou can specify other shipping methods such as Airmail, FEDEX or DHL. We shall let you know about the shipping cost after receipt of your order. It's more preferable for you to provide us with your own FEDEX/DHL account number so that the delivery charge can be charged directly from your account.
Technical Parameters
ModelBS--80ABS-150ABS-225ABS-408ABS-608ABS-800ABS-1000A
Inner Box Dimensions W*H*D(mm)400*500*400500*600*500600*750*600600*850*800800*950*8001000*1000*8001000*1000*1000
Outer Box Dimensions W*H*D(mm)650*1100*1100750*1200*1200750*1400*1500850*1600*18001050*1800*18001250*2050*18001250*2050*2000
Temperature Range-70-C150 ·C(180 ·C) (A 10C B 0C C-20C D-40C E-50C F-60C G-70C)
Temperature Resolution0.010C
Temperature Control Accuracy<2C
Temperature Fluctuation±20C
Heating/Cooling Time±50C
Power SupplyApproximately 30C/Approximately 10C(Conditions can be customized)
Item No.Parameter NameTechnical parameters
1.1Equipment NameProgrammable Constant Temperature and Humidity Chamber
1.2Equipment IntroductionThe Programmable Constant Temperature and Humidity Testing Machine, also known as the High-Low Temperature Alternating Damp Heat Testing Machine, falls under the category of large-scale climate simulation environmental equipment. It is suitable for conducting temperature and humidity aging tests on electrical and electronic products, including those used in new energy, automotive, household appliances, semiconductors, electronics, aerospace, universities and colleges, as well as instrumentation components. Specifically, it is applied to assess the adaptability of these products under environmental conditions such as high temperature, low temperature, damp heat, and alternating damp heat.
1.3Equipment ModelBS-150AG
1.4Effective Volume150L
1.5Internal Chamber Dimensions500*600*500 (W*H*D)(mm)
1.6External DimensionsFront-back Structure:750*1380*1450(W*H*D) (mm) Lateral Structure:1050*1380*950(W*H*D) (mm) ( Subject to the final confirmed 3D drawing )
1.7Temperature Range-70ºC~150ºC
1.8humidity range20~98%R. H (Temp. & Humidity Comparison Table)
1.9Heating Rate-40ºC ~ 150ºC ≥3ºC/min (Full-process Non-linearity & No-load Acceptance)
1.10Cooling Rate150ºC ~ -40ºC ≥1ºC/min (Full-process Non-linearity & No-load Acceptance)
1.11Temperature and Humidity Display AccuracyTemperature:0.01ºC Humidity:0.1%R.H
1.12Temperature and Humidity DeviationTemperature:±2ºC Humidity: When ≥75%RH, the humidity error shall be ≤+2 to -3%RH Humidity: When <75%RH, the humidity error shall be ≤+5%RH
1.13Temperature and Humidity FluctuationTemperature:≤±0.5ºC Humidity:+2/-3%R.H
1.14Temperature and Humidity UniformityTemperature:≤2ºC Humidity:+2/-3%R.H
1.15Cooling MethodAir Cooling
1.16Weight380KG
1.17Power380V/9.5KW
1.18OthersAll the above performance indicators refer to the data measured under the conditions of no load, no test sample, and ambient temperature of 25±2ºC. Operating Noise:70dB (measured at 1 meter from the chamber door and 1.5 meters in height).
Item No.StandardsExplanation of Standards
2.1General standardsGB/T2423.2-2008 Test Method: High Temperature
GB/T 2423.1-2008 Test method: Low Temperature
GJB150.4A-2009 Low Temperature Test Method
GJB150.3A-2009 High Temperature Test Method
G/BT 2423.4-2008/IEC6008-2-30:2005 Test Db: Alternating Damp Heat Method
GBT 2424.6-2006 Environmental Testing for Electrical and Electronic Products - Performance Qualification Report of Temperature and Humidity Test Chambers
GB/T10586-2006 Technical Specifications for Damp Heat Test Chambers
GBT 2424.5-2006 Environmental Testing for Electrical and Electronic products - Performance Qualification Report of Temperature Test Chambers
2.2Acceptance Execution StandardsManufacturing Standards:GB/T10586-2006,GB/T10592-2008
Verification Standards :GB/T5170.2-2017,GB/T5170.5-2016
Technical Standards: Acceptance shall be conducted in accordance with the signed technical index requirements
Item No.DescriptionTechnical Specification Parameters
3.1Cabinet StructureIntegrated (left-right/front-back) frame structure, welded with national standard channel steel. The equipment is sturdy and durable, with low vibration and low noise during operation, while ensuring the overall reliability and safety performance of the equipment.
3.2Inner Chamber MaterialIt adopts 1.0mm-thick SUS #304 stainless steel. The entire inner chamber is fully welded to ensure its sealing performance, with a reinforced bottom design that supports an average load of ≥300KG.
3.3Outer Shell MaterialIt adopts cold-rolled steel plates with a thickness of 1.2mm, featuring double-sided spraying treatment and a blue-white color(Customizable according to customer requirements, color samples or color codes are available upon request).
3.4Thermal Insulation MaterialThe thermal insulation layer has a thickness of 100mm and uses fire-resistant, high-strength rigid polyurethane foam insulation material. Thermal insulation coefficient: less than 0.0212 kcal/(m.hour).
3.5Cabinet Door StructureIt is a single door, a double-layer silicone rubber sealing strip is used between the door and the chamber to ensure sealing performance, featuring resistance to high and low temperatures and anti-aging properties. An anti-condensation and anti-frost electric heating device is installed on the door frame and door edge to prevent condensation from forming on the chamber surface.
3.6Test Observation WindowOne vacuum multi-layer explosion-proof glass viewing window is provided; the surrounding area of the window is equipped with coated heating for anti-frost protection to prevent water vapor condensation. A safe, high-brightness, energy-saving lighting lamp (with manual on/off control) is installed above the viewing window.
3.7Air Duct ComponentsIt adopts a circulating fan with a motor, an aluminum extended shaft, and a high/low temperature-resistant aluminum alloy multi-blade circulating fan, achieving forced convection vertical diffusion circulation. The air outlet is adjustable.
3.8Sample ShelfIt is made of stainless steel, equipped with 2 sets of brackets, and can be freely adjusted up and down (customizable according to customer requirements).
3.9Test PortOne test port with a diameter of 50mm is reserved on the left side of the chamber, and one set of silicone plug + sealing cover is provided.
3.10Three-Color Indicator LightGreen for normal operation, yellow for standby, and red for fault alarm.
3.11Drainage TroughDrainage troughs are provided around the interior of the cabinet, facilitating the discharge of condensed water and preventing internal water accumulation.
3.12Balance HoleA pressure balance hole is installed inside the chamber to balance the pressure between the inside and outside of the chamber.
3.13Swivel CasterSwivel casters are installed at the bottom of the equipment, facilitating the relocation, movement and positioning of the equipment.
Item No.DescriptionTechnical Specification Parameters
4.1Air Supply MethodIt adopts a forced internal circulation mode with top air supply and bottom air return. The air deflector at the air outlet can disperse cold and hot air to the entire interior of the chamber, ensuring uniform and stable distribution.
4.2Circulation MotorIt is a long-shaft motor, installed outside the chamber, avoiding the influence of temperature and humidity inside the chamber. The long shaft extends directly into the interior of the chamber, with silicone insulation and sealing.
4.3Centrifugal ImpellerIt is a multi-blade centrifugal circulating aluminum wind wheel, featuring light weight, large air volume, and high air pressure. Additionally, it exhibits resistance to high and low temperatures, a small expansion coefficient, and low operating noise.
4.4Circulating Air DuctThe circulating air duct is matched with the refrigeration and heating system, and the sealing plate is closely attached to the evaporator and heating tube, allowing the circulating air to fully absorb the cold energy from the evaporator and the heat energy from the heating tube.
4.5SensorClass A Platinum Resistance PT100+T Temperature and Humidity Sensor, featuring stable operation and accurate detection.
Item No.DescriptionTechnical Specification Parameters
5.1Refrigeration ModeCompressor-Based Refrigeration
5.2CompressorFrench "Tecumseh" Hermetic Compressor
5.3EvaporatorHigh-Efficiency Multi-Stage Fin-and-Tube Evaporator with Hydrophilic Coating (Thickened Fin Type)
5.4CondenserShell-and-Tube Condenser (Air-Cooled Type)
5.5RefrigerantFluoride-Free Eco-Friendly Refrigerant, DuPont (USA) R404A
5.6Thermal Expansion ValveThe core control logic of the thermal expansion valve is: The opening degree of the expansion valve is controlled by the superheat degree of the gaseous refrigerant at the evaporator outlet, thereby adjusting the flow rate of refrigerant entering the evaporator.
5.7Oil SeparatorThe core function of the oil separator is to separate the refrigerating oil and refrigerant, allowing each substance to perform its respective function as required and preventing oil films from reducing heat exchange efficiency.
5.8Filter-DrierThe filter-drier consists of two parts: the filter and the dryer. The filter is used to block solid particles such as iron filings, welding slag, and dirt, preventing them from clogging the passages; the dryer is used to absorb moisture circulating with the refrigerant, avoiding "ice blockage" inside the pipelines.
5.9Solenoid ValveDanfoss Solenoid Valve (for coarse adjustment of the cooling capacity of the entire refrigeration system)
5.10Leak Detection MethodNitrogen purging and pressure holding for 24 hours is adopted for leak detection testing of all pipelines in the entire system.
5.11Vibration Damping DesignCompressor Base and Vibration Isolation Treatment: The base features a water-leakage prevention design. It is a self-evaporating waterproof base that effectively prevents condensed water from leaking out. Vibration isolation treatment is applied to moving components such as the compressor and fan, achieving a low-noise design.
Item No.DescriptionTechnical Specification Parameters
6.1Heating MethodIt adopts an imported SSR (Solid-State Relay) for driving, featuring contactless control, no noise, no electric arc, and stable reliability.
6.2Heating TubeIt adopts a stainless steel finned nickel-chromium wire high-speed heater.
6.3Heating System and Electrical ComponentsIt is a completely independent system that does not affect the refrigeration and humidification systems. Temperature control is achieved through microcomputer calculation and PID automatic adjustment; the output power changes based on the comparison result between the actual temperature value and the set temperature value, so as to achieve high precision, high efficiency, and high stability. Major low-voltage electrical components all adopt products from well-known brands: "Schneider" AC contactors and thermal overload relays, "OMRON" small intermediate relays, and Delixi signal lamps, switches, and circuit breakers.
Item No.DescriptionTechnical Specification Parameters
7.1Humidification MethodIt is a fully automatic humidification module system with integrated closed-loop humidity control, designed and manufactured using advanced technology. It is an improved and upgraded multi-functional integrated humidification system,featuring superior characteristics such as fast humidification, high efficiency, ultra-low failure rate, and higher reliability. It adopts SSR-driven contactless control and intelligent PID automatic calculation to adjust output power.
7.2Water Level ControlIt features automatic water level control and automatic water filling functions, which make the humidification system more efficient, the control more stable, and the equipment operation more reliable. These functions avoid the drawback of high failure rates in humidification systems and overall improve the equipment's reliability.
7.3Humidification UnitIt features a closed integrated structure, which is easy to install and can be mounted outside the chamber/room. The system structure is simpler, more efficient, and more practical.
Item No.DescriptionTechnical Specification Parameters
8.1Control MethodColor Touch Screen + PLC Control System
8.2Screen Display7-inch screen with a resolution of 800*480, 65535 true colors, and LED backlight display; direct display of temperature and humidity set values (SV) and actual values (PV); Chinese/English language switchable display with true-color touch input; capable of displaying execution program number, segment number, remaining time, cycle times, and operation time; program editing and graphic curve display.
8.3Temperature and Humidity settingSet it independently according to the test temperature range requirements.
8.4Data LoggingBuilt-in recording program, the memory in the controller can store 3 months of 24hour operation data. It can automatically generate temperature and humidity curve files, data, operation records, alarm records, etc., and can display set values and actual values, cycle numbers, temperature segments, temperature values, time, etc. in both digital and graphical forms.
8.5External ConnectionCommunication methods such as USB, RS485, and LAN ports are supported, enabling external connection to a computer for full-function control, data storage, printing, and recording.
8.6Running ModeRated value/program/slope running mode.
8.7Input MethodRT100×2 (dry bulb and wet bulb) / 4~20mA, both built-in simultaneously
8.8Output MethodTemperature×1,Humidity×1,END×1,RUN×1,T1~T4, TROUBLE×1, H1×1, TIME SIGNAL×3.
8.9Display PrecisionTemperature:0.01ºC Humidity:0.01%RHT Time:0.01 seconds
8.10System Capacity1~120 test programs (i.e., can be divided into 120 program groups), maximum 1~1200 steps (i.e., 1200 action steps), and single-step time up to 9999 hours 59 minutes.
8.11Login MethodChinese/English Name Login, Chinese/English Test Login, Operation Time Display.
8.12Deviation CorrectionIt prevents parameter deviations caused by various factors; after correction, the temperature and humidity values can be more accurate and standardized.
8.13System FunctionsSequence Control, Reservation Control, Power-off Recovery, Fault Display.
8.14Password ControlMulti-level password protection can be set to prevent unauthorized use by non-operators and unauthorized modification of internal parameters.
Item No.Technical Specification Parameters
9.1The compressor adopts a system high-low pressure protection (device).
9.2Compressor Overload, Overcurrent, and Over-temperature Protection.
9.3Compressor Oil Lack Protection.
9.4Fan Overcurrent and Over-temperature Protection.
9.5Humidifier Water Lack Protection.
9.6Humidifier Dry-heating Over-temperature Protection.
9.7Humidification Liquid Level Protection Indication.
9.8Low-Temperature Non-Humidification Protection System.
9.9Power Phase Loss Protection, Phase Sequence Error Protection, Phase Unbalance Protection, Leakage Protection.
9.10Test Chamber Enclosure Grounding Protection.
9.11Independent Over-temperature Protection for Working Chamber.
Key PointSpecific Requirements
Space Requirements: Positioning & Handling, Installation Footprint Dimensions, and Placement Environment Requirements
11.2 Floor Space and Peripheral Relevant Dimensions
Space around the equipment shall comply with the following: A: ≥ 60cm; B≥ 60cm; C≥ 80cm; D≥ 80cm
The floor shall be level, with good ventilation, and free from flammable, explosive, corrosive gases and dust.
11.3 Other Environmental Requirements for Test Chamber OperationEnvironmental Temperature Requirements5~28ºC Ensure Optimal Performance
Humidity Requirements≤85%R.H
Air Pressure Requirements86KPa~106KPa
Electromagnetic EnvironmentThere shall be no strong vibration or strong electromagnetic radiation sources around the equipment.
Site DrainageA drainage floor drain shall be provided within 2 meters of the test chamber.
11.4 Safe Storage Conditions for Test ChambersWhen the test chamber is not in use, the storage environment of the test chamber shall be maintained at a temperature consistently above 0ºC.
Power and Related Conditions
11.5 Grounding RequirementsThe grounding resistance shall be less than 4Ω, with independent grounding (i.e., TN-S grounding system), and a three-phase five-wire AC power supply shall be adopted (it is strictly prohibited to mix the neutral wire and ground wire).
Item No.DescriptionService Content
12.1Equipment Warranty PeriodThe supplier shall provide a 1-year warranty for the test equipment starting from the date of acceptance. During the warranty period, fees such as material fees and repair fees shall be waived (excluding damages caused by human factors or natural disasters). The supplier commits to providing lifelong free technical support and conducting equipment operation consultation and inspection twice a year.
12.2Service Response TimeUpon receiving the customer's maintenance request notification, the supplier shall respond within 2 hours and arrive at the customer's site within 24 hours, making every effort to repair the product promptly. The company has sufficient spare parts to provide timely, fast, and high-quality services.
12.3After-Sales TeamThe company has a dedicated After-Sales Service Department, with more than 5 after-sales service engineers. Meanwhile, it has set up office-based service stations and built a comprehensive customer service system, as well as established customer files. In addition to providing technical consultation services to customers, the company is also responsible for collecting and organizing customer complaints and consultation information. It ensures that the problems and requirements raised by customers are handled in a timely manner, and tracks and verifies the handling status while establishing corresponding records. These efforts provide a basis for improving quality and enhancing products.
12.4List of Randomly Included DocumentsOne copy each of the Product User Manual, Instrument Operation Manual, Product Certificate of Conformity, and Product Warranty Card.
12.6Installation, Commissioning and TrainingAfter the equipment arrives at the buyer's factory, our party shall be responsible for the on-site installation, commissioning and trial operation of the equipment. Meanwhile, our party shall provide free training to the buyer's staff to ensure that the buyer's relevant personnel can independently complete all tests specified in the contract, perform equipment maintenance and troubleshoot basic faults.
12.7Installation, Commissioning and AcceptanceThe buyer shall be responsible for providing the external conditions required for equipment installation in accordance with the supplier's requirements, and the installation shall be conducted by our company. The supplier shall be responsible for on-site installation and commissioning at the buyer's location. After the completion of installation and commissioning, personnel from both the supplier and the buyer shall sign the commissioning and acceptance report to confirm approval.

Product details

Environmental Climatic Constant Rapid Temperature Change Humidity Programmable Climate Test Chamber Equipment /High and Low /Thermal Shock Testing Machine is a laboratory thermostat product (test machine) manufactured in China and available to buyers worldwide through the GoodsFromChina sourcing service. Typical uses include Industry, School, Hospital, Lab, Test Equipment.

Key features

  • Material: Stainless Steel
  • Type: Test Machine
  • Application: Industry, School, Hospital, Lab, Test Equipment
  • Power: 5.5kw
  • Voltage: 380V
  • Certification: CE, ISO
  • Warranty: 1 Years
  • Customized: Customized

The core control logic of the thermal expansion valve is

The opening degree of the expansion valve is controlled by the superheat degree of the gaseous refrigerant at the evaporator outlet, thereby adjusting the flow rate of refrigerant entering the evaporator.

The filter-drier consists of two parts

the filter and the dryer. The filter is used to block solid particles such as iron filings, welding slag, and dirt, preventing them from clogging the passages; the dryer is used to absorb moisture circulating with the refrigerant, avoiding "ice blockage" inside the pipelines.

Compressor Base and Vibration Isolation Treatment

The base features a water-leakage prevention design. It is a self-evaporating waterproof base that effectively prevents condensed water from leaking out. Vibration isolation treatment is applied to moving components such as the compressor and fan, achieving a low-noise design.

Space Requirements

Positioning & Handling, Installation Footprint Dimensions, and Placement Environment Requirements

Ordering & packaging

Minimum order quantity is 1 piece. Standard export packaging: Standard Export Strong Plywood Box. Lead time: 3-20days. HS code: 8479899990. Every order can include a pre-shipment quality inspection and consolidated shipping by sea, air or express, including DDP delivery.

How we source this product for you

  1. 1

    Send your inquiry

    Choose options, quantity and requirements. No payment needed.

  2. 2

    Get a factory quote

    We confirm price, MOQ and lead time — and compare alternatives.

  3. 3

    Production & inspection

    We follow up production and inspect goods before shipment.

  4. 4

    Delivered to your door

    Sea, air or express with customs clearance and DDP options.

Express5–8 days
Air freight8–12 days
Sea freight25–40 days
DDPDuties included

Frequently asked questions

What is the minimum order quantity for Environmental Climatic Constant Rapid Temperature Change?

The MOQ is 1 piece. Smaller trial orders can sometimes be negotiated — tell us your quantity in the inquiry.

How much does Environmental Climatic Constant Rapid Temperature Change cost?

The listed factory price is US$4,750.00 – 6,450.00 per piece, depending on quantity (larger orders get lower tier prices). Your final quote includes our service fee and shipping options.

Can it be customized with my logo or specifications?

Yes. The manufacturer offers customization — logo printing, packaging, colors or modified specifications. Describe your requirements in the inquiry form.

How long does production and shipping take?

Production lead time: 3-20days. Shipping to the US takes about 5–8 days by express, 8–12 days by air and 25–40 days by sea, with DDP door-to-door delivery available.

How do you check product quality?

We verify the manufacturer before ordering and can perform a pre-shipment inspection (AQL sampling) with a photo report before you pay the balance.